This EM 2400 unit is particularly useful for anyone with a substantially weakened pelvic floor or
who has difficulty contracting their pelvic floor muscles.
It can act as the first stage of an ongoing pelvic floor strengthening program,
helping you to re-establish your ability to identify and contract your pelvic floor muscles correctly.
Men can use this electrical stimulation with an anal probe.
Women DO NOT use electrical stimulation without first checking with your health professional or if you have an IUD or pessary.
This kit includes:
EM 2400 unit in pink
Vaginal probe included rectal probe available as separate order
instruction booklet
1 year replacement warranty
white carry case
The stimulator is easy to use and has 5 preset programmes. The programme type and the intensity of stimulation are controlled by push buttons. Technical information | MECHANISM | TECHICAL DESCRIPTION | 01 | Channel | Single channel | 02 | Pulse Amplitude | Adjustable, 0-80mA, Max output 80mA (peak to peak) into 500ohm load. | 03 | Output Voltage | Adjustable, 0-40V, Max output 40V (peak to peak) into 500ohm load. | 04 | Wave Form | Asymmetrical Rectangular Biphasic Pulse. | 05 | Power Supply | Two AA Batteries | 06 | Size | 9.2cm(L) x 6.2cm(W) x 2.85cm(H) | 07 | Weight | 145 grams (2 batteries included) | 08 | Pulse Rate | Pre-setting, 1~100 Hz | 09 | Pulse Width | Pre-setting, 150 µs, 200 µs or 250 µs | 10 | Programme | A, B, C, D, E, five pre-set programme of options. | 11 | Programme
A ,B, C, E | The programme details of A, B, C, E are as follows. Parameters are preset at fixed values. The 2 seconds ramp time includes 1 second ramp up, and 1 second ramp down. Each programme is repeated in a constant cyclic pattern.Programme | Rate | Width | Contraction | Relaxation | Ramp | Cycle | (Hz) | (µs) | (Sec.) | (Sec.) | (Sec.) | (Sec.) | A | 35 | 250 | 4 | 8 | 2 | 14 | B | 40 | 200 | 6 | 15 | 2 | 23 | C | 10 | 250 | 5 | 3 | 2 | 10 | E | 20 | 250 | 5 | 5 | 2 | 12 |
| 12 | Programme D | Programme D is composed of 12 sections with varied pulse rates. Each section contains 30 contractions. The 2 seconds ramp time includes 1 second ramp up, and 1 second ramp down. The complete programme lasts 60 minutes with 360 contractions. It is repeated in a constant cyclic pattern. The details of the programme are given below.Section | Rate | Width | Contraction | Relaxation | Ramp | Cycle | (Hz) | (µs) | (Sec.) | (Sec.) | (Sec.) | (Sec.) | 1 | 7 | 150 | 4 | 4 | 2 | 10 | 2 | 8 | 150 | 4 | 4 | 2 | 10 | 3 | 9 | 150 | 4 | 4 | 2 | 10 | 4 | 10 | 150 | 4 | 4 | 2 | 10 | 5 | 11 | 150 | 4 | 4 | 2 | 10 | 6 | 12 | 150 | 4 | 4 | 2 | 10 | 7 | 13 | 150 | 4 | 4 | 2 | 10 | 8 | 14 | 150 | 4 | 4 | 2 | 10 | 9 | 15 | 150 | 4 | 4 | 2 | 10 | 10 | 16 | 150 | 4 | 4 | 2 | 10 | 11 | 12 | 150 | 4 | 4 | 2 | 10 | 12 | 7 | 150 | 4 | 4 | 2 | 10 |
| 13 | Timer | Fixed at 30 minutes, treatment time countdown automatically. The output current will be shut off when the time is expired followed by a beep sound. | 14 | Operating Condition | Temperature:0° C ~ 40° C
Relative Humidity: 30%~75%
Atmosphere Pressure: 700Hpa~1060Hpa | 15 | Remark | There may be up to a +/-10% tolerance of all parameters and +/-20% tolerance of amplitude & voltage. |
|
|